Media 000664887: Inner Ear Endocast, Left
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000664887
Media type
Mesh
Object element or part
inner ear endocast, left
Object represented
Object taxonomy
Gerrhonotus ophiurus
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Meghan Forcellati
Date created
September 19, 2024
Date uploaded
September 19, 2024

FILE OBJECT DETAILS Field Definitions

File name
TCWC35604_Gerrhonotus-ophiurus_Left.ply
File format(s)
PLY
File size
6.46 MB
Points
92701
Polygons
185020
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
0.003, 0.003, 0.005
Centroid coordinates
0.010, 0.004, 0.022 (Vertex Mean)
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Texas A&M University
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Columbia Work Exemption Program Grant; Yale Institute for Biospheric Studies Small Grant; Laidlaw Fellowship; STRATA Program (National Science Foundation Grant EAR 2331991); Richard Gilder Graduate School; NSF DBI-1902242; AMNH Vertebrate Paleontology Travel Fund; Yale Biospheric Studies Early Grant
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object TCWC:Herpetology:35604 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
3000
Voltage
130
Power
--
Amperage
140
Surrounding material
0.25 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000159592: Head [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000159592: Head [CTImageSeries] [Etc] was processed to create derived Media 000664887: Inner Ear Endocast, Left [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Meghan Forcellati
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000664887: Inner Ear Endocast, Left [Mesh] [CT] (this media)