Media 000668537: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000668537: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000668537
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Acentrogobius ferox
Object organization
Side
--
Orientation
--
Short description
--
Full description
CT scan of MCZ 13149 Acentrogobius ferox
Creator
Diego F. B Vaz
Date created
June 24, 2021
Date uploaded
October 03, 2024
FILE OBJECT DETAILS Field Definitions
File name
MCZ13149_Acentrogobius_ferox_recon-zip.zip
File format(s)
ZIP archive, BMP
File size
3.88 GB
Image width
2184
Image height
2184
Color space
--
Color depth
8
Compression
0; BI_RGB; None
X pixel spacing
12.971086
Y pixel spacing
12.971086
Z pixel spacing
12.971086
Pixel spacing units
Um
Slice thickness
--
Number of images in set
2,207
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:Ich:13149
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Diego F. B. Vaz
Event date
June 24, 2021
Software
1.7
Description
CT scan of MCZ 13149, Acentrogobius ferox
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
3600 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
(ON) 3
Projections
480
Voltage
30 kV
Power
--
Amperage
150 uA
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
0.1200
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000668537: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Diego F. B Vaz
Event date
June 24, 2021
Software
NRecon
Description
--
Description attachment
None
Processing Activity 1:
Software
NRecon
Description
Media produced by this event on MorphoSource
Media 000668537: Whole Body [CTImageSeries] [CT] (this media)