Media 000058159: Whole Body Micro Ct
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000058159
Media type
Mesh
Object element or part
Whole body microCT
Object represented
Object organization
Side
NotApplicable
Orientation
--
Short description
STL Files
Full description
Migrated MorphoSource 1 Media File Title: STL Files Migrated MorphoSource 1 Media Group Title: Ptychoglossus vallensis
Creator
--
Date created
--
Date uploaded
September 20, 2018

FILE OBJECT DETAILS Field Definitions

File name
Ptychoglossus_vallensis_AMNH119239.stl
File format(s)
STL
File size
1020 MB
Points
2694897
Polygons
5381466
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.775, 9.771, 42.163
Centroid coordinates
4.817, 5.473, 24.209
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, General Electric Inspection Technology California (General Electric Inspection Technology)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:herpetology:119239 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
General Electric Inspection Technology California (General Electric Inspection Technology)
Creator
Henry Towbin, Morgan Hill
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2862
Voltage
100-200
Power
--
Amperage
80-160
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000058159: Whole Body Micro Ct [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Henry Towbin, Morgan Hill
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000058159: Whole Body Micro Ct [Mesh] [CT] (this media)