Media 000653019: Partial Braincase
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000653019
Media type
Volumetric Image Series
Object element or part
Partial Braincase
Object represented
Object taxonomy
Ngamugawi wirngarri
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Ruth Williams
Date created
--
Date uploaded
July 28, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
17.2 MB
Image width
328
Image height
294
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
X pixel spacing
9.000000
Y pixel spacing
9.000000
Z pixel spacing
9.000000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
512

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1076 with modified camera, Adelaide Microscopy (University of Adelaide)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Museum Victoria
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
This work was supported by the Australian Research Council.
Publisher
--
Cite as
Clement et al. (2024) Nature Communications
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nmv:p:231504 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Adelaide Microscopy (University of Adelaide)
Creator
Ruth Williams
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4.1 sec
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
--
Voltage
100 kV
Power
--
Amperage
70 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
360 deg
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000653019: Partial Braincase [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000653019: Partial Braincase [CTImageSeries] [CT] (this media)