Media 000368539: Incus
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000368539
Media type
Mesh
Object element or part
incus
Object represented
Object taxonomy
Cheirogaleus major
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Megan Hennon
Date created
June 14, 2021
Date uploaded
June 18, 2021

FILE OBJECT DETAILS Field Definitions

File name
mnhn.zm.CG_2001-2105_C.major_incus85196.ply
File format(s)
PLY
File size
132 KB
Points
2126
Polygons
4248
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
0.002, 0.002, 0.001
Centroid coordinates
0.012, 0.027, 0.013
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1174, MorphOptics - Biogéosciences (L'université de Bourgogne)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
MNHN-Paris
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mnhn:zm:CG 2001-2105 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
MorphOptics - Biogéosciences (L'université de Bourgogne)
Creator
Margot Bernardi, Sébastien Couette, Emilie Steimetz
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4.4
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
380
Voltage
50
Power
0.04
Amperage
800
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000085196: Basicranium [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Margot Bernardi, Sébastien Couette, Emilie Steimetz
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000085196: Basicranium [CTImageSeries] [Etc] was processed with 2 activities to create derived Media 000368539: Incus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Megan Hennon
Event date
June 14, 2021
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Dragonfly
Description

Processing Activity 2: Smoothing/Noise Reduction

Software
Dragonfly
Description
1 iteration

Media produced by this event on MorphoSource

Media 000368539: Incus [Mesh] [CT] (this media)