Media 000607137: Patella
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

GENERAL DETAILS Field Definitions

Media ID
000607137
Media type
Mesh
Object element or part
Patella
Object represented
Object taxonomy
Tapirus sp.
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Lou Moizo
Date created
February 15, 2019
Date uploaded
February 26, 2024

FILE OBJECT DETAILS Field Definitions

File name
Tapirus_pinchaque_1982_34_Left_Patella.ply
File format(s)
PLY
File size
3.29 MB
Points
90656
Polygons
181296
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.238, 4.299, 4.021
Centroid coordinates
3.035, 2.148, 2.246
Units of point coordinates
Cm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x L 240, AST-RX: X-ray Tomography Technical Platform (Muséum National d'Histoire Naturelle)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
MNHN-Paris
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
ERC Gravibone
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MNHN:ZM:AC-1982-34 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
AST-RX: X-ray Tomography Technical Platform (Muséum National d'Histoire Naturelle)
Creator
Marta Bellato
Event date
--
Software
DATOX/RES
Description
X Pixel Spacing = 0.0449 mm, Y Pixel Spacing = 0.0449 mm, Z Pixel Spacing = 0.0449 mm
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000607137: Patella [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Lou Moizo
Event date
February 15, 2019
Software
Avizo
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000607137: Patella [Mesh] [CT] (this media)