Media 000510202: Segmentation Of The Internal Venous System
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000510202
Media type
Mesh
Object element or part
Segmentation of the internal venous system
Object represented
Object taxonomy
Alligator mississipiensis
Side
--
Orientation
--
Short description
Alligator mississippiensis all cranial vessels STL file
Full description
Alligator mississippiensis OUVC 9757 - segmented all cranial vessels STL file
Creator
--
Date created
--
Date uploaded
March 31, 2023

FILE OBJECT DETAILS Field Definitions

File name
Alligator_mississippiensis__OUVC_9757_all_vessels_STL.stl
File format(s)
STL
File size
91.7 MB
Points
970192
Polygons
1922832
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
59.806, 140.217, 41.377
Centroid coordinates
34.156, 76.040, 24.349
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Hi Speed FX-I Helical CT scanner, OhioHealth O'Bleness Hospital (OhioHealth O'Bleness Hospital)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ouvc:h:9757 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
OhioHealth O'Bleness Hospital (OhioHealth O'Bleness Hospital)
Creator
--
Event date
--
Software
--
Description
X Pixel Spacing: 0.09 mm, Y Pixel Spacing: 0.09 mm, Z Pixel Spacing: 0.09 mm
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000510202: Segmentation Of The Internal Venous System [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000510202: Segmentation Of The Internal Venous System [Mesh] [CT] (this media)