Media 000599488: Upper Second Molar
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000599488
Media type
Mesh
Object element or part
Upper second molar
Object represented
Object taxonomy
Paromomys farrandi
Side
Left
Orientation
--
Short description
UCMP 224139
Full description
UCMP 224139 Paromomys farrandi M2
Creator
Hovatter, Brody T.
Date created
--
Date uploaded
January 25, 2024

FILE OBJECT DETAILS Field Definitions

File name
Paromomys_farrandi_M2_UCMP224139.ply
File format(s)
PLY
File size
18.1 MB
Points
500106
Polygons
999755
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
0.013, 0.046, 0.008
Centroid coordinates
0.012, 0.009, 0.007
Units of point coordinates
M

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker Skyscan 1172, Laboratory of Sharlene Santana (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
University of California Regents; University of California Museum of Paleontology
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:224139 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Laboratory of Sharlene Santana (University of Washington)
Creator
--
Event date
--
Software
--
Description
X Pixel Spacing = 9.25 µm, Y Pixel Spacing = 9.25 µm, Z Pixel Spacing = 9.25 µm
Description attachment
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000599488: Upper Second Molar [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Nrecon
Description

Processing Activity 2: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000599488: Upper Second Molar [Mesh] [CT] (this media)