Media 000445830: Right Inner Ear
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000445830
Media type
Mesh
Object element or part
right inner ear
Object represented
Object taxonomy
Europasaurus holgeri
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Schade, Marco
Date created
--
Date uploaded
June 06, 2022

FILE OBJECT DETAILS Field Definitions

File name
DFMMh-FV_581.1_-_right_inner_ear.ply
File format(s)
PLY
File size
21 MB
Points
296460
Polygons
592930
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
27.127, 17.112, 15.795
Centroid coordinates
54.769, 79.737, 57.122
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Metrotom 1500, Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Dinosaurierpark Münchehagen
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
Dinosaurierpark Münchehagen
Cite as
Marco Schade provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)
Creator
Schade, Marco
Event date
October 26, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1000 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
220 kV
Power
--
Amperage
343 µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000445178: Braincase [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000445830: Right Inner Ear [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Schade, Marco
Event date
--
Software
amira
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
amira
Description

Media produced by this event on MorphoSource

Media 000445830: Right Inner Ear [Mesh] [CT] (this media)