Media 000116156: Right Humerus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000116156: Right Humerus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000116156
Media type
Volumetric Image Series
Object element or part
Right humerus
Object represented
Object taxonomy
Kambara sp.
Object organization
Side
--
Orientation
--
Short description
QM_F56060_Murgon_DICOM_Archive
Full description
Migrated MorphoSource 1 Media File Title: QM_F56060_Murgon_DICOM_Archive Migrated MorphoSource 1 Media Group Title: QM F56060 Murgon DICOM Archive
Creator
--
Date created
--
Date uploaded
May 18, 2020
FILE OBJECT DETAILS Field Definitions
File name
QM_F56060_Murgon_DICOM_Archive.zip
File format(s)
ZIP archive, DICOM
File size
786 MB
Image width
768
Image height
768
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.071925
Y pixel spacing
0.071925
Z pixel spacing
--
Pixel spacing units
Mm
Slice thickness
7.1925E-2
Number of images in set
2,085
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Inveon Multimodal Platform, University of New South Wales - Lowy Cancer Research Centre (University of New South Wales)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Michael Stein and colleagues provided access to these dataoriginally appearing in Stein et al., 2020 with data collection funded by DE150100862, DP140102656, DP140102659, DP130100197, DP170101420 and DP180100792. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
qm:f:56060
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
University of New South Wales - Lowy Cancer Research Centre (University of New South Wales)
Creator
T. Hung
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000116156: Right Humerus [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
T. Hung
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000116156: Right Humerus [CTImageSeries] [Etc] (this media)