Media 000606274: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000606274
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Vombatus ursinus
Side
--
Orientation
--
Short description
HRXCT scan skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0911 Rowe: Vombatus: Scans of the skull of Vombatus ursinus (TMM M-2953; exchange from Manash University, Victoria, Australia; previous number 2364 [Department of Zoology, Monash University]) for Dr. Timothy Rowe of the Department of Geological Sciences, The University of Texas at Austin, and Digimorph. Specimen scanned by Matthew Colbert 03 September 2003. 16bit: 1024x1024 16-bit TIFF images. P250D, 420 kV, 1.8 mA, 2 brass filters, empty container wedge, no offset, integration time 32 ms, slice thickness 0.5 mm, S.O.D. 664 mm, 1000 views, one ray averaged per view, one sample per view, inter-slice spacing 0.45 mm, field of reconstruction 132 mm (maximum field of view 137 mm), reconstruction offset 6200, reconstruction scale 2200. Total slices = 399.
Creator
Matthew Colbert
Date created
September 03, 2003
Date uploaded
February 20, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
449 MB
Image width
984
Image height
775
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.128900
Y pixel spacing
0.128900
Z pixel spacing
0.450000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
399

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, IIS-0208675
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant IIS-0208675 to Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:2953 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000606274: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000606274: Skull [CTImageSeries] [CT] (this media)