Media 000606296: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000606296
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Odocoileus virginianus
Side
--
Orientation
--
Short description
HRXCT scan skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1313 Rowe: odo: Scans of a white-tailed deer skull of Odocoileus virginianus (TMM M-2683, central TX) for Tim Rowe and Digimorph of the University of Texas at Austin. Specimen scanned by Richard Ketcham 23 September 2005. Scanned in two parts (odo (414 slices) and odoH (218 slices)) that were appended; interslice spacing doubled to 0.6 mm for odoH. 16bit: 1024x1024 16-bit TIFF images. P250D, 419 kV, 1.8 mA, no filter, empty container wedge, 190% offset, 32 ms integration time, slice thickness 1 line (= 0.3125 mm), S.O.D. 746 mm, 1000 views, 1 sample per view, inter-slice spacing 1 line (= 0.3 mm) for slices 1-414 and 1 line (=0.6 mm) for slices 415-630, field of reconstruction 299.4 mm (maximum field of view 299.41 mm), reconstruction offset 8000, scanner scale 5000, reconstruction scale 1600. Reconstructed with an angle of -10 degrees. OdoH reconstructed with y offset -4.02. Total final slices = 630.
Creator
Richard Ketcham
Date created
September 23, 2005
Date uploaded
February 20, 2024

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
473 MB
Image width
547
Image height
1001
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.290000
Y pixel spacing
0.290000
Z pixel spacing
0.300000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
630

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242, IIS-0208675
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by NSF grant IIS-0208675 to Tim Rowe. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:2683 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000606296: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000606296: Skull [CTImageSeries] [CT] (this media)