Media 000168179: Cranial Endocast
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000168179: Cranial Endocast
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000168179
Media type
Mesh
Object element or part
Cranial endocast
Object represented
Object taxonomy
Octomys mimax
Object organization
Side
--
Orientation
--
Short description
Mesh file
Full description
Migrated MorphoSource 1 Media File Title: Mesh file Migrated MorphoSource 1 Media Group Title: X-ray microtomography
Creator
--
Date created
--
Date uploaded
December 11, 2020
FILE OBJECT DETAILS Field Definitions
File name
IMCN_CM_024_M86745-168179.ply
File format(s)
PLY
File size
69.2 MB
Points
942986
Polygons
1885988
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.601, 15.285, 28.322
Centroid coordinates
14.104, -16.286, 14.888
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Y-TEC (YPF and CONICET)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On Any Repository
Funding attribution
ANPCyT, PICT 2016-2881
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
imcn:cm:024
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Y-TEC (YPF and CONICET)
Creator
--
Event date
March 10, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000348696: Cranium [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
March 10, 2021
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Description
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000348696: Cranium [CTImageSeries] [CT]
was processed
to create
derived
Media 000168179: Cranial Endocast [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Bernarda Epele
Event date
March 04, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000168179: Cranial Endocast [Mesh] [CT] (this media)