Media 000369998: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000369998
Media type
Volumetric Image Series
Object element or part
whole body
Object taxonomy
Chamaeleo chamaeleon
Side
--
Orientation
--
Short description
DiceCT scan of Chamaeleo chamaeleon juvenile
Full description
--
Creator
--
Date created
April 18, 2019
Date uploaded
July 11, 2021

FILE OBJECT DETAILS Field Definitions

File name
UCMVZ_DiceCT_for_morphosource.zip
File format(s)
ZIP archive, TIFF
File size
1.25 GB
Image width
809
Image height
593
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.035000
Y pixel spacing
0.035000
Z pixel spacing
0.035000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,592

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, X-ray Computed Tomography Facility (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mvz:amphibian and reptile specimens:236481 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
X-ray Computed Tomography Facility (University of Washington)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1000
Voltage
65 kV
Power
--
Amperage
700 uA
Surrounding material
styrofoam, cheese cloth
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
391.888 mm
Source detector distance
666.203 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000369998: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Northstar Imaging
Description

Media produced by this event on MorphoSource

Media 000369998: Whole Body [CTImageSeries] [CT] (this media)