Media 000564834: Head
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000564834: Head
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000564834
Media type
Mesh
Object element or part
head
Object represented
Object taxonomy
Chironius grandisquamis
Object organization
Side
--
Orientation
--
Short description
--
Full description
mesh from microCT volume, data inverted following CT scan
Record created by batch submission.
Creator
Chandrashekar, Chirag
Date created
January 13, 2022
Date uploaded
September 21, 2023
FILE OBJECT DETAILS Field Definitions
File name
UCM_HERP_55761_Chironius_grandisquamis_head_MESH.stl
File format(s)
STL
File size
1.68 GB
Points
5424350
Polygons
10408008
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.671, 48.873, 13.815
Centroid coordinates
10.816, 27.471, 7.664
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm), Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Colorado Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN partner NSF DBI-1701714; oMeso PEN NSF DBI-2001474
Publisher
University of Colorado Museum of Natural History
Cite as
UCM [catalog number]
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UCM:Herp:UCM:Herp:55761
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
Creator
Braker, Emily
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1601
Voltage
120
Power
9.96e-06
Amperage
75
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000438963: Head [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Braker, Emily
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000438963: Head [CTImageSeries] [CT]
was processed
to create
derived
Media 000564834: Head [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Chandrashekar, Chirag
Event date
July 18, 2023
Software
--
Description
Reconstructed tomography to mesh, with smoothing and noise reduction
Description attachment
None
Media produced by this event on MorphoSource
Media 000564834: Head [Mesh] [CT] (this media)