Media 000417875: Sesamoid
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000417875: Sesamoid
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000417875
Media type
Volumetric Image Series
Object element or part
sesamoid
Object represented
Object taxonomy
Carpolestes simpsoni
Object organization
Side
--
Orientation
--
Short description
--
Full description
bone #304b in original skeleton documentation. ID as shown in Bloch and Boyer 2002
Previously incorrectly identified as a trapezium
Creator
Gabriel Yapuncich
Date created
January 04, 2018
Date uploaded
January 28, 2022
FILE OBJECT DETAILS Field Definitions
File name
UMMP101963_Csimps_304b_trapezium.zip
File format(s)
ZIP archive, TIFF
File size
6.05 MB
Image width
206
Image height
162
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.010000
Y pixel spacing
0.010000
Z pixel spacing
0.010000
Pixel spacing units
--
Slice thickness
--
Number of images in set
101
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Paleontology
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ummp:vp:101963
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Event date
August 25, 2009
Software
scanco medical software
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 3 activities
to create
derived
Media 000417875: Sesamoid [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Gabriel Yapuncich
Event date
January 04, 2018
Software
scanco medical software, ImageJ
Description
reconstruction done with scanco medical in 2009 from sinograms
Description attachment
None
Processing Activity 1: Reconstruction
Software
scanco medical software
Description
Processing Activity 2: Transform: Rotation
Software
ImageJ
Description
Processing Activity 3: Crop
Software
ImageJ
Description
Media produced by this event on MorphoSource
Media 000417875: Sesamoid [CTImageSeries] [CT] (this media)