Media 000422615: Intermediate Phalanx 2 (Ip2)
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000422615
Media type
Mesh
Object element or part
intermediate phalanx 2 (IP2)
Object represented
Object taxonomy
Carpolestes simpsoni
Object organization
Side
--
Orientation
--
Short description
--
Full description
bone #misc4 in original skeleton documentation. ID as shown in Bloch and Boyer 2002
Creator
Gabriel Yapuncich
Date created
January 26, 2018
Date uploaded
February 17, 2022

FILE OBJECT DETAILS Field Definitions

File name
UMMP101963_Csimps_misc4_IP2_smooth.ply
File format(s)
PLY
File size
8.28 MB
Points
119478
Polygons
238948
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.883, 1.490, 1.393
Centroid coordinates
1.269, 0.937, 0.966
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (4 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Paleontology
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummp:vp:101963 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Event date
August 25, 2009
Software
scanco medical software
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 3 activities to create derived Media 000417793: Intermediate Phalanx 2 (Ip2) [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Gabriel Yapuncich
Event date
January 05, 2018
Software
ImageJ
Description
reconstruction done with scanco medical in 2009 from sinograms
Description attachment
None

Processing Activity 1: Reconstruction

Software
scanco medical software
Description

Processing Activity 2: Transform: Rotation

Software
ImageJ
Description

Processing Activity 3: Crop

Software
ImageJ
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000417793: Intermediate Phalanx 2 (Ip2) [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000422615: Intermediate Phalanx 2 (Ip2) [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Gabriel Yapuncich
Event date
January 26, 2018
Software
Avizo
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000422615: Intermediate Phalanx 2 (Ip2) [Mesh] [CT] (this media)