Media 000043275: Lumbar
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000043275: Lumbar
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000043275
Media type
Volumetric Image Series
Object element or part
Lumbar
Object represented
Object taxonomy
Plesiadapis cookei
Object organization
Side
Unknown
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: MicroCT Volume & Derivative Mesh Files Migrated MorphoSource 1 Media File Description: Represents Bone A in Figure 31 of Boyer & Gingerich (2018) Migrated MorphoSource 1 Media Group Description: Represents Bone A in Figure 31 of Boyer & Gingerich (2018)
Creator
--
Date created
--
Date uploaded
March 07, 2018
FILE OBJECT DETAILS Field Definitions
File name
Lumbar-1.zip
File format(s)
ZIP archive, TIFF
File size
73.3 MB
Image width
516
Image height
466
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.034698
Y pixel spacing
0.034698
Z pixel spacing
0.034698
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
589
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
University of Michigan Museum of Paleontology
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1440742 (to DM Boyer and GF Gunnell), BCS 1440588 (to JI Bloch), and BCS 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UMMP:VP:87990
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Barbara Zhao
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2000
Voltage
182
Power
0.0
Amperage
112
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000043275: Lumbar [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer, Barbara Zhao
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000043275: Lumbar [CTImageSeries] [Etc] (this media)