Media 000056416: Dentary
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000056416: Dentary
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000056416
Media type
Mesh
Object element or part
dentary
Object represented
Object taxonomy
Plesiadapis cookei
Object organization
Side
Left
Orientation
--
Short description
Mesh file
Full description
Migrated MorphoSource 1 Media File Title: Mesh file Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media File Description: correct chirality Migrated MorphoSource 1 Media Group Description: Boyer and Gingerich (2018: not figured)
Creator
--
Date created
--
Date uploaded
August 12, 2018
FILE OBJECT DETAILS Field Definitions
File name
UM87990_l-dent.ply
File format(s)
PLY
File size
54.2 MB
Points
749996
Polygons
1499952
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.068, 42.098, 66.258
Centroid coordinates
22.953, 21.865, 32.357
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
University of Michigan Museum of Paleontology
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by BCS 1440742, 1440588, 1552848. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UMMP:VP:87990
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.708
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2000
Voltage
175
Power
0.014175
Amperage
81
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000056415: Dentary [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000056415: Dentary [CTImageSeries] [Etc]
was processed
to create
derived
Media 000056416: Dentary [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000056416: Dentary [Mesh] [Etc] (this media)