Media 000009470: Cranium
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000009470: Cranium
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000009470
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Homunculus patagonicus
Object organization
Side
--
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: ct volume data and derivative mesh files
Creator
--
Date created
--
Date uploaded
February 19, 2016
FILE OBJECT DETAILS Field Definitions
File name
Homunculus.1.surface2.ply
File format(s)
PLY
File size
16.3 MB
Points
447773
Polygons
899674
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
36.091, 38.616, 73.377
Centroid coordinates
27.788, 22.043, 34.576
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
SMiF
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Richard Kay provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mpm:pv:3502
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Lauren Gonzales
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
165
Power
0.023100000000000002
Amperage
140
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000009345: Cranium [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Lauren Gonzales
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000009345: Cranium [CTImageSeries] [Etc]
was processed
to create
derived
Media 000009470: Cranium [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Lauren Gonzales
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000009470: Cranium [Mesh] [Etc] (this media)