Media 000013994: M/2 Or M/3
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000013994: M/2 Or M/3
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000013994
Media type
Mesh
Object element or part
M/2 or M/3
Object represented
Object taxonomy
Peradectes protinnominatus
Object organization
Side
Left
Orientation
--
Short description
raw surface file
Full description
Migrated MorphoSource 1 Media File Title: raw surface file Migrated MorphoSource 1 Media Group Title: M/2 or M/3 Migrated MorphoSource 1 Media Group Description: Scan is mirrored relative to specimen.
Creator
--
Date created
--
Date uploaded
June 16, 2016
FILE OBJECT DETAILS Field Definitions
File name
CAB12-1767_raw.ply
File format(s)
PLY
File size
54.9 MB
Points
746134
Polygons
1493000
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1.880, 1.893, 1.419
Centroid coordinates
1.211, 1.262, 0.732
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Florida Museum of Natural History
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DGE 1315138
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: N.S. Vitek provided access to these dataoriginally appearing in Vitek et al. 2017 , the collection of which was funded by NSF DGE 1315138. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:VP:329146
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
708
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
1500
Voltage
125
Power
0.0050999999999999995
Amperage
41
Surrounding material
cotton
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000013993: M/2 Or M/3 [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000013993: M/2 Or M/3 [CTImageSeries] [Etc]
was processed
to create
derived
Media 000013994: M/2 Or M/3 [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000013994: M/2 Or M/3 [Mesh] [Etc] (this media)