Media 000021070: Hippocampus
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000021070
Media type
Mesh
Object element or part
Hippocampus
Object represented
Object taxonomy
Macropus eugenii
Side
--
Orientation
--
Short description
Meug1982_Hippocampus_STL
Full description
Migrated MorphoSource 1 Media File Title: Meug1982_Hippocampus_STL Migrated MorphoSource 1 Media Group Title: Meugenii_1982 DICOMs & STLs Migrated MorphoSource 1 Media Group Description: This scan was made under UQ ANRFA/SBS/531/12
Creator
--
Date created
--
Date uploaded
January 16, 2017

FILE OBJECT DETAILS Field Definitions

File name
Meug1982_Hippocampus_001.stl
File format(s)
STL
File size
2.29 MB
Points
24040
Polygons
48072
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
4.735, 2.985, 2.809
Centroid coordinates
5.128, 8.084, 9.251
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Inveon Multimodal Platform, The Centre for Advanced Imaging (National Imaging Facility) (University of Queensland)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object l-vw:canb-meug9182 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The Centre for Advanced Imaging (National Imaging Facility) (University of Queensland)
Creator
Karine Mardon
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000021409: Skull & Brain [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Karine Mardon
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000021409: Skull & Brain [CTImageSeries] [CT] was processed to create derived Media 000021070: Hippocampus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Karine Mardon
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000021070: Hippocampus [Mesh] [CT] (this media)