Media 000022642: Ct Scan Of Skeleton And Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000022642
Media type
Volumetric Image Series
Object element or part
CT scan of skeleton and skull
Object represented
Object taxonomy
Scaphiopus holbrookii
Side
--
Orientation
--
Short description
Tiff-stack
Full description
Migrated MorphoSource 1 Media File Title: Tiff-stack Migrated MorphoSource 1 Media Group Title: CT scan of UF-H-9620, Scaphiopus holbrookii
Creator
--
Date created
--
Date uploaded
February 13, 2017

FILE OBJECT DETAILS Field Definitions

File name
UF9620-Zstack.zip
File format(s)
ZIP archive, TIFF
File size
4.07 GB
Image width
1543
Image height
869
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.029622
Y pixel spacing
0.029622
Z pixel spacing
0.029622
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,854

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
University of Florida
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:9620 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1800
Voltage
100
Power
0.025
Amperage
250
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000022642: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000022642: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc] (this media)