Media 000028246: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000028246
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Rhacophorus catamitus
Object organization
Side
--
Orientation
--
Short description
A-53981
Full description
Migrated MorphoSource 1 Media File Title: A-53981 Migrated MorphoSource 1 Media Group Title: CT scan of Rhacophorus catamitus specimen
Creator
--
Date created
--
Date uploaded
July 08, 2017

FILE OBJECT DETAILS Field Definitions

File name
A-53981_21June2017.7z
File format(s)
application/x-7z-compressed
File size
674 MB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.042000
Y pixel spacing
0.042000
Z pixel spacing
0.042000
Pixel spacing units
Mm
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Shimadzu SMX-100CT, Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Alexander S. Hall
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DEB-1146324
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Kyle A O'Connell provided access to these dataoriginally appearing in ZooTaxa , the collection of which was funded by NSF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uta:uta-a:53981 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)
Creator
Alexander S. Hall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1200
Voltage
55
Power
--
Amperage
40
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000028246: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Alexander S. Hall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000028246: Element Unspecified [CTImageSeries] [Etc] (this media)