Media 000026326: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000026326: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000026326
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Alouatta seniculus seniculus
Object organization
Side
NotApplicable
Orientation
--
Short description
zipped dicom stack
Full description
Migrated MorphoSource 1 Media File Title: zipped dicom stack Migrated MorphoSource 1 Media Group Title: medical CT volume data Migrated MorphoSource 1 Media File Description: correct chirality Migrated MorphoSource 1 Media Group Description: correct chirality
Creator
--
Date created
--
Date uploaded
May 17, 2017
FILE OBJECT DETAILS Field Definitions
File name
AMNH188009_Alouatta.zip
File format(s)
ZIP archive, DICOM
File size
227 MB
Image width
275
Image height
511
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.641285
Y pixel spacing
0.643387
Z pixel spacing
0.400000
Pixel spacing units
Mm
Slice thickness
0.6
Number of images in set
1,419
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Perspective 64 Computed, NC State Veterinary Hospital, Diagnostic Imaging Department (North Carolina State University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1552848
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF BCS 1552848. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Mammals:M-188009
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NC State Veterinary Hospital, Diagnostic Imaging Department (North Carolina State University)
Creator
James Robey
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
na
Power
--
Amperage
na
Surrounding material
air/fluid
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000026326: Whole Body [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
James Robey
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000026326: Whole Body [CTImageSeries] [Etc] (this media)