Media 000380713: Hyoid Elements Of Galeopterus Variegatus
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000380713
Media type
Volumetric Image Series
Object element or part
Hyoid elements of Galeopterus variegatus
Object represented
Object taxonomy
Galeopterus variegatus
Side
Midline
Orientation
--
Short description
--
Full description
--
Creator
Peishu Li
Date created
August 30, 2021
Date uploaded
August 30, 2021

FILE OBJECT DETAILS Field Definitions

File name
Galeopterus_hyoid_scansheet.zip
File format(s)
ZIP archive, TIFF
File size
74.7 MB
Image width
722
Image height
659
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.018960
Y pixel spacing
0.018960
Z pixel spacing
0.018960
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
464

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Mammals:141132 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Peishu Li
Event date
August 30, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
--
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1000
Voltage
50
Power
0.013
Amperage
260
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000380713: Hyoid Elements Of Galeopterus Variegatus [CTImageSeries] [CT] (this media)