Media 000363758: Skull
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000363758: Skull
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000363758
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Ambystoma maculatum
Object organization
Side
NotApplicable
Orientation
--
Short description
Skull with colored elements
Full description
Skull with elements colored as seen in Blackburn Lab Sketchfab model:
Creator
Jaimi Gray
Date created
May 14, 2021
Date uploaded
May 14, 2021
FILE OBJECT DETAILS Field Definitions
File name
Ambystoma-maculatum-skull.ply
File format(s)
PLY
File size
132 MB
Points
4293154
Polygons
1431066
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
15.773, 14.730, 10.908
Centroid coordinates
-0.004, -0.528, -0.205
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:26607
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2200
Voltage
90
Power
0.018
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000038447: 16bit Tiffs [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000038447: 16bit Tiffs [CTImageSeries] [Etc]
was processed
with 1 activity
to create
derived
Media 000363758: Skull [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Jaimi Gray
Event date
May 14, 2021
Software
VG Studio Max and Blender
Description
Skull with elements colored as seen in Blackburn Lab Sketchfab model:
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
VG Studio Max and Blender
Description
Skull elements isolated and meshes generated in VG Studio Max. Meshes cleaned/edited in Blender.
Media produced by this event on MorphoSource
Media 000363758: Skull [Mesh] [CT] (this media)