Media 000346380: Skull
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000346380
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Tantilla coronata
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
February 25, 2021

FILE OBJECT DETAILS Field Definitions

File name
3541.ply
File format(s)
PLY
File size
6.61 MB
Points
164569
Polygons
330436
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
6.742, 3.583, 2.680
Centroid coordinates
0.615, -0.091, 0.508
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object GSU:GSU-Herp:3541 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
January 10, 2021
Software
Phoenix Datos|X
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333096
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
3
Projections
2000
Voltage
70
Power
10.5
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
0.01471641
Detector pixels Y
--
Detector pixels size Y
0.01471641
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
Yes
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000346380: Skull [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
February 25, 2021
Software
VGStudioMax
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
VGStudioMax 3.4
Description
Segmentation and Mesh creation

Media produced by this event on MorphoSource

Media 000346380: Skull [Mesh] [CT] (this media)