Media 000494799: Cranium
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000494799
Media type
Mesh
Object element or part
cranium
Object represented
Object taxonomy
Arctodictis sinclairi
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
January 30, 2023

FILE OBJECT DETAILS Field Definitions

File name
ArctodictisSinclairiMLP85VII31_cranium.stl
File format(s)
STL
File size
9.9 MB
Points
103849
Polygons
207616
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
158.240, 76.938, 218.201
Centroid coordinates
7.250, 1.644, -4.369
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Philips Brillance 64, Equipo de Neurocirurgía Endovascular Radiología Intervencionista (ENERI) (Clinica La Sagrada Familia)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museo de La Plata
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Gaillard, C., MacPhee, R.D.E. & Forasiepi, A.M. Seeing through the eyes of the sabertooth Thylacosmilus atrox (Metatheria, Sparassodonta). Commun Biol 6, 257 (2023). https://doi.org/10.1038/s42003-023-04624-5
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MLP:85-VII-3-1 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Equipo de Neurocirurgía Endovascular Radiología Intervencionista (ENERI) (Clinica La Sagrada Familia)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
120
Power
--
Amperage
271
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
182
Detector pixels size X
0.400
Detector pixels Y
101
Detector pixels size Y
0.400
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000494799: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000494799: Cranium [Mesh] [CT] (this media)