Media 000373052: Cranium
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000373052
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Chelydropsis murchisoni
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
July 30, 2021
Date uploaded
July 30, 2021

FILE OBJECT DETAILS Field Definitions

File name
Chelydropsis_murchisoni_BSPG1980I158_Cranium.ply
File format(s)
PLY
File size
79.3 MB
Points
1886290
Polygons
3779328
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
64185.833, 91854.039, 37615.254
Centroid coordinates
35427.797, 53885.239, 22454.961
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211, CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object snsb-bspg:1980I158 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
Creator
Joyce, Walter
Event date
February 10, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
120 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
165 kV
Power
--
Amperage
147 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000354170: Cranium [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Joyce, Walter
Event date
February 10, 2020
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000354170: Cranium [CTImageSeries] [CT] was processed to create derived Media 000373052: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Serjoscha Evers
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000373052: Cranium [Mesh] [CT] (this media)