Media 000363015: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000363015: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000363015
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Hamptophryne boliviana
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - whole body
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1377
Cannatella:
Hamptophryne: Scans of a whole alcohol-preserved Hamptophryne boliviana (TNHC 44565; La Paz trail, Iparia, Peru; coll: J.P. & J.E. Bogart 19 Jan. 1968) for David Cannatella of The University of Texas Department of Biological Sciences and Amphibian AToL. Specimen scanned by Matthew Colbert 9 January 2006.
16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.05456 mm), S.O.D. 80 mm, 1600 views, 2 samples per view, inter-slice spacing 2 lines (= 0.05456 mm), field of reconstruction 25.7 mm (maximum field of view 26.18995 mm), reconstruction offset 6800, scanner scale 6200, reconstruction scale 1800. Acquired with 15 slices per rotation. Drift- and ring-removal processing done by Alison Mote based on correction of raw sinogram data using IDL routines “RK_SinoDeDrift” with parameter “driftlength=21” and “RK_SinoRingProcSimul” with default parameters. Reconstructed with an angle of -6 degrees. Rotation correction processing done using IDL program “DoRotationCorrection.” Last 4 blank slice deleted. Total final slices = 986.
Creator
--
Date created
January 09, 2006
Date uploaded
May 10, 2021
FILE OBJECT DETAILS Field Definitions
File name
TNHC_44565.zip
File format(s)
ZIP archive, TIFF
File size
2.12 GB
Image width
966
Image height
540
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.025100
Y pixel spacing
0.025100
Z pixel spacing
0.054560
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
986
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Natural History Collections
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334952, DBI-1902242
Publisher
oUTCT PEN
Cite as
David Cannatella provided access to these data, with data collection funded by NSF EF-0334952 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
TNHC:Herpetology:44565
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
January 09, 2006
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1600
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000363015: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
May 10, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000363015: Whole Body [CTImageSeries] [CT] (this media)