Media 000365695: Whole Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000365695
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Luetkenotyphlus brasiliensis
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
June 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
MCP_2062_BODY_Rec.zip
File format(s)
ZIP archive
File size
893 MB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.020915
Y pixel spacing
0.020915
Z pixel spacing
0.020915
Pixel spacing units
Mm
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Instituto do Petróleo e dos Recursos Naturais (Pontifícia Universidade Católica do Rio Grande do Sul - PUCRS)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCP:2062 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Instituto do Petróleo e dos Recursos Naturais (Pontifícia Universidade Católica do Rio Grande do Sul - PUCRS)
Creator
--
Event date
May 25, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
800 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
--
Voltage
45 kV
Power
--
Amperage
60 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000365695: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
June 02, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000365695: Whole Body [CTImageSeries] [CT] (this media)