Media 000408628: Head
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000408628: Head
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000408628
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Saguinus oedipus
Object organization
Side
--
Orientation
--
Short description
CET-108
Full description
diceCT stained
Creator
Caitlin Yoakum
Date created
December 20, 2021
Date uploaded
December 20, 2021
FILE OBJECT DETAILS Field Definitions
File name
YoakumC_CET-108_Stained_MW_TIF.zip
File format(s)
ZIP archive, TIFF
File size
5.25 GB
Image width
1276
Image height
1792
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.034167
Y pixel spacing
0.034167
Z pixel spacing
0.034167
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,450
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, MICRO - MicroCT Imaging Consortium for Research and Outreach (University of Arkansas)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DDRIG 1944642
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
du:ea:262
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
MICRO - MicroCT Imaging Consortium for Research and Outreach (University of Arkansas)
Creator
Caitlin Yoakum
Event date
October 31, 2020
Software
CT 3D Pro
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.41/708
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
3141
Voltage
210
Power
--
Amperage
130
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
-500
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000408628: Head [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Caitlin Yoakum
Event date
December 20, 2021
Software
VG Studio Max
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000408628: Head [CTImageSeries] [CT] (this media)