Media 000368631: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Media 000368631: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000368631
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Saguinus fuscicollis
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - mandible
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0782
Ryan:
leoAB: Scans of the mandibles of Saguinus fuscicollis (USNM 194331 and USNM 194334 (female); Uvini, Rio Cosireni, Peru) for Timothy Ryan of the Duke Primate Center, Duke University. Scanned by Matthew Colbert, 03 December 2002. USNM 194331 is positioned with its teeth up in the scans, USNM 194334 is positioned with its teeth down. USNM 194334 is also taller.
16bit: 1024x1024 16-bit TIFF images. II, 120 kV, 0.20 mA, no filter, air wedge, no offset, slice thickness = 1 line (= 0.0237 mm), S.O.D. 115 mm, 1000 views, 2 samples per view, inter-slice spacing = 1 line (= 0.0237 mm), field of reconstruction 22.91 mm, reconstruction offset 6000, reconstruction scale 900. Acquired with 25 slices per rotation. Total slices = 1400.
8bit: 8-bit JPG version of the above the images.
Creator
Matthew Colbert
Date created
December 03, 2002
Date uploaded
June 19, 2021
FILE OBJECT DETAILS Field Definitions
File name
USNM_194331.zip
File format(s)
ZIP archive, TIFF
File size
2.74 GB
Image width
522
Image height
866
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.022400
Y pixel spacing
0.022400
Z pixel spacing
0.023700
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,400
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by Tim Ryan. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
usnm:mammals:194331
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000368631: Element Unspecified [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000368631: Element Unspecified [CTImageSeries] [CT] (this media)