Media 000376657: Eubaena Cephalica Braincase Endocast
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000376657
Media type
Mesh
Object element or part
Eubaena cephalica - Braincase Endocast
Object represented
Object taxonomy
Eubaena cephalica
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Evers, Serjoscha; Ferreira, Gabriel
Date created
August 11, 2021
Date uploaded
August 11, 2021

FILE OBJECT DETAILS Field Definitions

File name
Eubaena_cephalica_DMNH_96004_Endocast.ply
File format(s)
PLY
File size
116 MB
Points
1549553
Polygons
3099102
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
16.328, 13.491, 36.780
Centroid coordinates
22.997, 33.344, 38.140
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211, CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Denver Museum of Nature and Science
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Ferreira et al. 2021. Contrasting brains and bones: neuroanatomical evolution of turtles (Testudinata)
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dmnh:96004 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1800
Voltage
180
Power
--
Amperage
78
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000056542: A Nearly Complete Skull Of Eubaena Cephalica [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

STEP 3: IMAGE PROCESSING

Derived Media 000056542: A Nearly Complete Skull Of Eubaena Cephalica [CTImageSeries] [Etc] was processed to create derived Media 000376657: Eubaena Cephalica Braincase Endocast [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Ferreira, Gabriel, Evers, Serjoscha
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000376657: Eubaena Cephalica Braincase Endocast [Mesh] [CT] (this media)