Media 000379145: Lumbar Vertebra 03, Lumbar Vertebra 01, Thoracic Vertebra 11, Thoracic Vertebra 12, Lumbar Vertebra 02, Thoracic Vertebra 10
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000379145
Media type
Volumetric Image Series
Object element or part
lumbar vertebra 03; lumbar vertebra 01; thoracic vertebra 11; thoracic vertebra 12; lumbar vertebra 02; thoracic vertebra 10
Object represented
Object taxonomy
Tolypeutes matacus
Side
--
Orientation
--
Short description
Reconstructed Image stack
Full description
--
Creator
Zack, Ellianna H.
Date created
--
Date uploaded
August 22, 2021

FILE OBJECT DETAILS Field Definitions

File name
FMNH_28342_Tolypeutes_matacus_ImageStack.zip
File format(s)
ZIP archive, TIFF
File size
526 MB
Image width
833
Image height
761
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.027465
Y pixel spacing
0.027465
Z pixel spacing
0.027465
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,019

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Mammals:28342 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Smith, Stephanie M.
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0:12:00
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
950
Voltage
100 kV
Power
--
Amperage
240 uA
Surrounding material
foam
X-ray tube type
240
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
bone
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000379145: Lumbar Vertebra 01, Lumbar Vertebra 02, Lumbar Vertebra 03, Thoracic Vertebra 10, Thoracic Vertebra 11, Thoracic Vertebra 12 [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Zack, Ellianna H.
Event date
--
Software
GE phoenix datos|x; VGStudio
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
GE phoenix datos|x
Description

Processing Activity 2: Align Parts

Software
VGStudio
Description

Media produced by this event on MorphoSource

Media 000379145: Lumbar Vertebra 01, Lumbar Vertebra 02, Lumbar Vertebra 03, Thoracic Vertebra 10, Thoracic Vertebra 11, Thoracic Vertebra 12 [CTImageSeries] [CT] (this media)