Media 000388716: Shell Of Venericor
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000388716: Shell Of Venericor
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000388716
Media type
Mesh
Object element or part
shell of Venericor
Object represented
Object taxonomy
Venericor sp.
Object organization
Side
Left
Orientation
--
Short description
Left valve of shell
Full description
--
Creator
Katie Collins
Date created
September 03, 2021
Date uploaded
October 05, 2021
FILE OBJECT DETAILS Field Definitions
File name
1_fast_default.stl
File format(s)
STL
File size
28.3 MB
Points
294803
Polygons
593394
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
33.270, 64.935, 62.034
Centroid coordinates
-1.638, 4.538, -35.331
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
NHM London
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nhmuk:PI TB 14675
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Collins, Katie S.
Event date
September 03, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
2499
Voltage
180
Power
0.05796
Amperage
322
Surrounding material
plastic foam sheet
X-ray tube type
--
Target type
Reflection
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
1600
Detector pixels size X
0.0599
Detector pixels Y
1600
Detector pixels size Y
0.0599
Detector configuration
--
Source object distance
391.2017
Source detector distance
--
Target material
Tungsten
Rotation number
--
Phase contrast
--
Optical magnification
No
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000388716: Shell Of Venericor [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Katie Collins
Event date
September 03, 2021
Software
VG StudioMax
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000388716: Shell Of Venericor [Mesh] [CT] (this media)