Media 000582438: Femur
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000582438
Media type
Mesh
Object element or part
Femur
Object represented
Object taxonomy
Palaeopropithecus sp.
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Fabio Alfieri
Date created
November 18, 2023
Date uploaded
November 18, 2023

FILE OBJECT DETAILS Field Definitions

File name
Palaeopropithecus_ingens_MNHM_MAD-8808.ply
File format(s)
PLY
File size
26.1 MB
Points
374974
Polygons
749948
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
59.349, 45.311, 195.355
Centroid coordinates
-10.461, -11.908, 0.341
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
RX Solutions EasyTom 150, Montpellier Resources Imagerie: Institut des Sciences de l’Evolution de Montpellier (MRI-ISEM) (Université de Montpellier)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
MNHN-Paris
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mnhn.f:mad:8808 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Montpellier Resources Imagerie: Institut des Sciences de l’Evolution de Montpellier (MRI-ISEM) (Université de Montpellier)
Creator
Alfieri Fabio
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
100 kV
Power
--
Amperage
210 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000391901: Femur [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000391901: Femur [CTImageSeries] [CT] was processed to create derived Media 000582438: Femur [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Fabio Alfieri
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000582438: Femur [Mesh] [CT] (this media)