Media 000406406: Coracoid
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000406406
Media type
Mesh
Object element or part
Coracoid
Object represented
Object taxonomy
Ichthyornis dispar
Side
Right
Orientation
--
Short description
Almost complete right coracoid
Full description
--
Creator
Field, Daniel; Benito, Juan
Date created
--
Date uploaded
December 09, 2021

FILE OBJECT DETAILS Field Definitions

File name
YPM_1733_-_Coracoid_right.stl
File format(s)
STL
File size
1.79 MB
Points
18822
Polygons
37531
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
14.886, 8.162, 29.578
Centroid coordinates
5.133, 0.010, 21.965
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620 Versa x-ray microscope (xrm), Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VP:YPM VP 001733 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Event date
--
Software
--
Description
YPM 1724 and 1733 (scanned together): XTek CT XT H 225 Scanner at Harvard CNS. 90μA, 95kV, 1 second exposure, average 2 frames, 3200 views, no ring artifact correction, tungsten target, no filter. Voxel size = 0.0416 mm
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000406406: Coracoid [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Field, Daniel, Benito, Juan
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000406406: Coracoid [Mesh] [CT] (this media)