Media 000635173: Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000635173
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Bunomeryx sp.
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Selina Viktor Robson
Date created
June 04, 2024
Date uploaded
June 05, 2024

FILE OBJECT DETAILS Field Definitions

File name
MCZ_VPM_5311_Bunomeryx_jpegs.zip
File format(s)
ZIP archive, JPEG
File size
53.6 MB
Image width
1140
Image height
1342
Color space
RGB
Color depth
8
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.049206
Y pixel spacing
0.049206
Z pixel spacing
0.049206
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,999

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620 Versa x-ray microscope (xrm), Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:VP:VPM-5311 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
150 kV
Power
--
Amperage
280 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000635173: Cranium [CTImageSeries] [CT] (this media)