Media 000405390: Rib 2
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000405390: Rib 2
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
ยท Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000405390
Media type
Mesh
Object element or part
Rib 2
Object represented
Object taxonomy
Ichthyornis sp.
Object organization
Side
--
Orientation
--
Short description
Thoracic rib 2
Full description
--
Creator
Field, Daniel; Benito, Juan
Date created
--
Date uploaded
December 07, 2021
FILE OBJECT DETAILS Field Definitions
File name
FHSM_18702_-_Rib_3.stl
File format(s)
STL
File size
176 KB
Points
1809
Polygons
3601
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
42.016, 40.432, 12.234
Centroid coordinates
35.646, -1.185, -53.292
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FHSM:vp:18702
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
FHSM VP-18702 (main block): NSI scanner at UTCT. Feinfocus source, high power, 170 kV, 0.225 mA, 1 aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 597.681 mm, source to detector 1316.685 mm, continuous CT scan, 2 frames averaged, 0 skip frames, 2550 projections, 6 gain calibrations, 15 mm calibration phantom, data range [-5, 50] (grayscale range adjusted from NSI defaults), beam-hardening correction = 0.4. Voxel size = 0.1163 mm. Total slices = 1811.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000405390: Rib 2 [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Field, Daniel, Benito, Juan
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000405390: Rib 2 [Mesh] [CT] (this media)