Media 000414671: Sternum (Retopologised)
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000414671
Media type
Mesh
Object element or part
Sternum (Retopologised)
Object represented
Object taxonomy
Ichthyornis sp.
Side
--
Orientation
--
Short description
--
Full description
Retopologised mesh model of the sternum of Ichthyornis specimen FHSM VP 18702
Creator
Demuth, Oliver
Date created
January 18, 2022
Date uploaded
January 18, 2022

FILE OBJECT DETAILS Field Definitions

File name
FHSM_orig_GPA_exp.obj
File format(s)
OBJ
File size
676 KB
Points
10836
Polygons
21292
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.340, 4.303, 2.839
Centroid coordinates
0.000, 0.000, 0.000
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FHSM:vp:18702 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
FHSM VP-18702 (block containing sternum, distal carpometacarpus and pedal phalanx): NSI scanner at UTCT. Feinfocus source, high power, 170 kV, 0.225 mA, 1 aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 341.114 mm, source to detector 1316.685 mm, continuous CT scan, 2 frames averaged, 0 skip frames, 2550 projections, 6 gain calibrations, 15 mm calibration phantom, data range [-0.75, 9] (grayscale range adjusted from NSI defaults), beam-hardening correction = 0.15. Voxel size = 0.058 mm. Total slices = 1727.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000399358: Sternum [Mesh] [CT].

Processing Details Field Definitions

Creator
Field, Daniel, Benito, Juan
Event date
--
Software
VgStudio Max
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
VGStudio Max
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000399358: Sternum [Mesh] [CT] was processed with 1 activity to create derived Media 000414671: Sternum (Retopologised) [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Demuth, Oliver
Event date
--
Software
VgStudio Max
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Autodesk Maya
Description
Retopology

Media produced by this event on MorphoSource

Media 000414671: Sternum (Retopologised) [Mesh] [CT] (this media)