Media 000405646: Radius
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000405646
Media type
Mesh
Object element or part
Radius
Object represented
Object taxonomy
Ichthyornis dispar
Side
Left
Orientation
--
Short description
Complete left radius
Full description
--
Creator
Field, Daniel; Benito, Juan
Date created
--
Date uploaded
December 07, 2021

FILE OBJECT DETAILS Field Definitions

File name
KUVP_25472_-_Radius_left.stl
File format(s)
STL
File size
3.58 MB
Points
37507
Polygons
75019
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.625, 5.659, 62.539
Centroid coordinates
4.344, 9.606, 0.967
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas Biodiversity Institute
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object KU:KUVP:25472 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
KUVP 25471 (humerus), 25472 (radius and ulna), 123459 (carpometacarpus) (scanned together): NSI scanner at UTCT. Feinfocus source, high power, 200 kV, 0.145 mA, no filter, Perkin Elmer detector, 0.5 pF gain, 2 fps (499.893 ms integration time), no binning, no flip, source to object 124.123 mm, source to detector 1090.684 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-10, 126] (rescaled from NSI default), beam-hardening correction = 0.3. Voxel size = 0.0344 mm. Total slices = 1827.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000405646: Radius [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Field, Daniel, Benito, Juan
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000405646: Radius [Mesh] [CT] (this media)