Media 000527807: Cervical And Thoracic Vertebrae Of Specimens Ku:Kuvp:25472 And Ku:Kuvp:119673
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000527807
Media type
Volumetric Image Series
Object element or part
Cervical and thoracic vertebrae of specimens KU:KUVP:25472 and KU:KUVP:119673
Object represented
Object taxonomy
Ichthyornis dispar
Side
Midline
Orientation
--
Short description
--
Full description
Scan includes vertebrae from specimens KU:KUVP:25472 and KU:KUVP:119673. Most thoracic and cervical vertebrae and vertebral fragments correspond to specimen KU:KUVP:25472. A single posterior thoracic/unfused first sacral vertebra corresponds to specimen KU:KUVP:119673. This vertebrae includes a large amount of radiopaque inclusions. See "contents" file for further description of the included material.
Creator
Colbert, Mathew
Date created
--
Date uploaded
May 30, 2023

FILE OBJECT DETAILS Field Definitions

File name
KUVP_25472_and_119673_Vertebrae.zip
File format(s)
ZIP archive, TIFF
File size
3.68 GB
Image width
1761
Image height
1651
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.019800
Y pixel spacing
0.019800
Z pixel spacing
0.019800
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
845

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas Biodiversity Institute
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object KU:KUVP:25472 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Colbert, Matthew
Event date
--
Software
--
Description
--
Description attachment
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3600
Voltage
200 kV
Power
--
Amperage
0.145 mA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
71.071 mm
Source detector distance
1090.684 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000527807: Cervical And Thoracic Vertebrae Of Specimens Ku:Kuvp:25472 And Ku:Kuvp:119673 [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Colbert, Mathew
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000527807: Cervical And Thoracic Vertebrae Of Specimens Ku:Kuvp:25472 And Ku:Kuvp:119673 [CTImageSeries] [CT] (this media)