Media 000406387: Sternum
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000406387
Media type
Mesh
Object element or part
Sternum
Object represented
Object taxonomy
Ichthyornis dispar
Side
Midline
Orientation
--
Short description
Partial and fragmentary sternum
Full description
--
Creator
Field, Daniel; Benito, Juan
Date created
--
Date uploaded
December 09, 2021

FILE OBJECT DETAILS Field Definitions

File name
YPM_1450_-_Sternum.stl
File format(s)
STL
File size
43.3 MB
Points
443570
Polygons
904385
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.570, 19.298, 26.270
Centroid coordinates
-5.358, 2.328, -0.275
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VP:YPM VP 001450 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
--
Event date
--
Software
--
Description
YPM 1450 (Sternum): Nikon Metrology XT 5.4 High Resolution CT Scanner. 60 kV, 74 µA, no filter, source to object 97.3438 mm, source to detector 714.1293 mm, 1080 projections, 2 frames per projection, Voxel size = 0.0273 mm. Total slices = 3142
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000406387: Sternum [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Field, Daniel, Benito, Juan
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000406387: Sternum [Mesh] [CT] (this media)