Media 000407089: Coracoid Sternal
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000407089
Media type
Mesh
Object element or part
Coracoid sternal
Object represented
Object taxonomy
Ichthyornis dispar
Side
Right
Orientation
--
Short description
Sternal fragment of the right coracoid
Full description
--
Creator
Field, Daniel; Benito, Juan
Date created
--
Date uploaded
December 10, 2021

FILE OBJECT DETAILS Field Definitions

File name
RMM5937_-_Coracoid_sternal.stl
File format(s)
STL
File size
11.5 MB
Points
121128
Polygons
241040
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
13.916, 3.489, 16.390
Centroid coordinates
4.968, 5.961, 1.420
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object msc:5937 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
MSC 5937 and 6202 (scanned together): NSI scanner at UTCT. Feinfocus source, high power, 200 kV, 0.13 mA, no filter, Perkin Elmer detector, 0.5 pF gain, 2 fps (499.893 ms integration time), no binning, no flip, source to object 143 mm, source to detector 1091.513 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-10, 243] (grayscale range adjusted from NSI defaults), beam-hardening correction = 0.2. Voxel size = 0.0175 mm. Total slices = 981.
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000407089: Coracoid Sternal [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Field, Daniel, Benito, Juan
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000407089: Coracoid Sternal [Mesh] [CT] (this media)