Media 000431191: Epiplastron
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000431191
Media type
Mesh
Object element or part
Epiplastron
Object represented
Object taxonomy
Chelydropsis aubasi
Side
Left
Orientation
--
Short description
Syntype
Full description
--
Creator
Yann Rollot
Date created
February 25, 2021
Date uploaded
March 16, 2022

FILE OBJECT DETAILS Field Definitions

File name
Epiplastron_left_CHC.2.ply
File format(s)
PLY
File size
6.5 MB
Points
98911
Polygons
197804
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9222.402, 43375.701, 41654.797
Centroid coordinates
55172.106, 45793.091, 46549.534
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211, CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nmb:CHC.2 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
Creator
Walter Joyce
Event date
February 25, 2021
Software
--
Description
X pixel spacing: 0.045 mm Y pixel spacing: 0.045 mm Z pixel spacing: 0.045 mm
Description attachment
None
Reference attachment
None
Exposure time
90
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
180
Power
--
Amperage
35
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
1920
Detector pixels size X
0.045
Detector pixels Y
1536
Detector pixels size Y
0.045
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000431191: Epiplastron [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Yann Rollot
Event date
--
Software
Amira
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000431191: Epiplastron [Mesh] [CT] (this media)