Media 000431264: Xiphiplastron
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000431264: Xiphiplastron
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000431264
Media type
Mesh
Object element or part
Xiphiplastron
Object represented
Object taxonomy
Chelydropsis aubasi
Object organization
Side
Left
Orientation
--
Short description
Syntype
Full description
--
Creator
Yann Rollot
Date created
February 25, 2021
Date uploaded
March 16, 2022
FILE OBJECT DETAILS Field Definitions
File name
Xiphiplastron_left_CHC251.ply
File format(s)
PLY
File size
8.25 MB
Points
123730
Polygons
247444
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
14489.500, 32109.498, 49780.301
Centroid coordinates
67989.539, 43981.927, 53496.293
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211, CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nmb:CHC.251
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
Creator
Walter Joyce
Event date
February 25, 2021
Software
--
Description
X pixel spacing: 0.045 mm
Y pixel spacing: 0.045 mm
Z pixel spacing: 0.045 mm
Description attachment
None
Reference attachment
None
Exposure time
90
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
180
Power
--
Amperage
35
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
1920
Detector pixels size X
0.045
Detector pixels Y
1536
Detector pixels size Y
0.045
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000431264: Xiphiplastron [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Yann Rollot
Event date
--
Software
Amira
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000431264: Xiphiplastron [Mesh] [CT] (this media)