Media 000436796: Right Premaxilla
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000436796: Right Premaxilla
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000436796
Media type
Mesh
Object element or part
Right Premaxilla
Object represented
Object taxonomy
Gestemys powelli
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Pablo González Ruiz
Date created
April 28, 2022
Date uploaded
April 28, 2022
FILE OBJECT DETAILS Field Definitions
File name
Premaxillae.stl
File format(s)
STL
File size
107 KB
Points
1096
Polygons
2188
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.858, 8.940, 5.817
Centroid coordinates
-16.751, -4.617, -4.717
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner, Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
IBIGEO:P:107
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Departamento de Imágenes FUESMEN (Fundación Escuela de Medicina Nuclear (FUESMEN))
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
139 kV
Power
--
Amperage
140µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000436676: Element Unspecified [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Pablo González Ruiz, Hernández del Pino
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000436676: Element Unspecified [CTImageSeries] [CT]
was processed
to create
derived
Media 000436796: Right Premaxilla [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Pablo González Ruiz
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000436796: Right Premaxilla [Mesh] [CT] (this media)