Media 000458822: Entire Specimen
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000458822: Entire Specimen
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000458822
Media type
Volumetric Image Series
Object element or part
entire specimen
Object represented
Object taxonomy
Cnesterodon decemmaculatus
Object organization
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Record created by batch submission.
Creator
Zach Randall
Date created
--
Date uploaded
September 02, 2022
FILE OBJECT DETAILS Field Definitions
File name
KU_Fish_22415.zip
File format(s)
ZIP archive, TIFF
File size
869 MB
Image width
436
Image height
663
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.018396
Y pixel spacing
0.018396
Z pixel spacing
0.018396
Pixel spacing units
Mm
Slice thickness
0.01839566
Number of images in set
1,928
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas Biodiversity Institute Ichthyology Collection
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714; NSF DBI-1701932
Publisher
--
Cite as
University of Kansas Center for Research Inc provided access to these data, the collection of which was funded by oVert TCN; NSF DBI-1701714; NSF DBI-1701932. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
KU:KUI:22415
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zach Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250.097
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
960
Voltage
80
Power
0.016
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2024
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
73.33671576
Source detector distance
797.32613998
Target material
tungston
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000458822: Entire Specimen [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Zach Randall
Event date
--
Software
DatosX|R
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000458822: Entire Specimen [CTImageSeries] [CT] (this media)